Revit Can’t Place Light Fixtures?

Troubleshooting: Issues with Placing Light Fixtures in Revit

Placing light fixtures in Revit can sometimes cause frustration, particularly when you receive warnings like “Can’t place inserts outside hosts.” Understanding the underlying reasons for this issue and knowing how to address them can streamline your workflow and enhance your project design.

Understanding the Warning Message

One common issue encountered when trying to place light fixtures is the warning about not being able to place inserts outside of hosts. This typically arises when the light fixture you are trying to place is not associated with a proper host element. For example, if you are attempting to place a light fixture near a door that lacks a wall host, Revit will not allow it, as there’s no appropriate surface to anchor the fixture.

Steps to Place Light Fixtures Correctly

  1. Select the Appropriate View: Begin by opening the desired floor plan or ceiling plan where you intend to place the light fixture. This can be done through the Project Browser by navigating to Views > Floor Plans.

  2. Use the Right Tool: Navigate to the Systems tab on the ribbon, then select the Electrical panel. Click on the Lighting Fixture option.

  3. Choose Your Fixture Type: In the Type Selector dropdown, select the specific type of lighting fixture you wish to place. This is important, as different fixtures may have varying placement requirements.

  4. Enable Tagging: Ensure that the option for Tag on Placement is activated. This feature automatically places a tag on the fixture once it is positioned.

  5. Placing the Fixture: With the correct fixture type selected, move your cursor to the location where you want to place the fixture. Click to place it in the desired position.

  6. Check Host Elements: If you receive the warning regarding hosts, examine the area where you are placing the fixture. Ensure your fixture is being placed in a location with an appropriate host, such as on walls or ceilings. If necessary, adjust your fixture’s position to remain within the boundaries of the host object.

Troubleshooting Light Rendering Issues

Should you find that your lights are not rendering when you expect them to, follow these steps:

  1. Lighting Scheme Selection: Verify that the selected lighting scheme in your view settings allows for artificial lights. Some schemes like ‘Interior: Sun only’ will not render fixtures.

  2. Modify Rendering Settings: If applicable, adjust the rendering settings to ensure that artificial lights are included. Access the rendering dialog and select a suitable lighting scheme that incorporates such lights.

  3. Test with Fixtures: After making changes, conduct a test render to see if the artificial lights appear correctly.

Additional Considerations for Lighting Placement

  • Load Fixture Families: Ensure that the lighting fixture families you intend to use are loaded into your project. Without the appropriate families, Revit cannot place the fixtures regardless of the settings.

  • Placement on Surfaces: If you do not have a ceiling or walls, consider using face-based lighting fixtures that can be placed directly on surfaces.

  • Switch and Control Integration: If applicable, make sure to integrate your light fixtures with the appropriate control systems or switches. You can do this by selecting your fixtures and adding them to a switch system in the Switch Systems tab.

Frequently Asked Questions

1. Why can’t I see my light fixtures after placing them in Revit?
This issue could be related to the view’s visibility settings or the selected lighting scheme. Ensure that the fixtures are not hidden in the current view and that the lighting scheme allows for artificial lighting rendering.

2. What are face-based lighting fixtures, and how do I use them?
Face-based lighting fixtures are designed to be placed directly on surfaces like walls or ceilings without requiring a defined host. To use them, simply select the fixture type and click on the surface where you want to insert them.

3. How do I adjust the lighting intensity of my fixtures in Revit?
Select your lighting fixture and navigate to the Type Properties panel. You can duplicate the type if needed, then modify the Initial Intensity values to enhance or reduce the brightness of your fixture.

About the author

Wei Zhang

Wei Zhang

Wei Zhang is a renowned figure in the CAD (Computer-Aided Design) industry in Canada, with over 30 years of experience spanning his native China and Canada. As the founder of a CAD training center, Wei has been instrumental in shaping the skills of hundreds of technicians and engineers in technical drawing and CAD software applications. He is a certified developer with Autodesk, demonstrating his deep expertise and commitment to staying at the forefront of CAD technology. Wei’s passion for education and technology has not only made him a respected educator but also a key player in advancing CAD methodologies in various engineering sectors. His contributions have significantly impacted the way CAD is taught and applied in the professional world, bridging the gap between traditional drafting techniques and modern digital solutions.